ISO 5356-1 PDF

INTERNATIONAL. STANDARD. ISO. Third edition. Anaesthetic and respiratory equipment —. Conical connectors —. Part 1: Cones and. EN ISO Anaesthetic And Respiratory Equipment – Conical Connectors – Part 1: Cones And Sockets (Iso ) Defines dimensional and. I.S. EN ISO Anaesthetic and respiratory equipment -. Conical connectors – Part 1: Cones and sockets (ISO ).

Author: Jur Brajin
Country: Switzerland
Language: English (Spanish)
Genre: Sex
Published (Last): 7 March 2010
Pages: 352
PDF File Size: 7.74 Mb
ePub File Size: 12.58 Mb
ISBN: 666-1-93731-391-5
Downloads: 48270
Price: Free* [*Free Regsitration Required]
Uploader: Dukree

As the voice of the U. Live Chat Powered by jivochat. Need more than one copy? Gage Crib Worldwide, Inc. We use cookies to make our website easier to use and to better understand your needs. It gives requirements for the following cones and sockets: Please download Chrome or Firefox or view our browser tips.

Please first verify your email before subscribing to alerts. If the document is revised or amended, you will be notified by email. This part of ISO specifies the requirements and dimensions for conical connectors used in anaesthetic and respiratory equipment. Already Subscribed to this document. ISO Introduction In clinical practice, several breathing attachments used in anaesthetic and respiratory equipment may have to be joined together to provide a suitable breathing system.

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. Requirements for screw-threaded weight-bearing conical connectors are specified in ISO To minimize the risk of 22 mm connectors being accidentally disconnected, latching connectors can be used.

ISO ; Anesthetic and Respiratory Equipment – Conical Connectors

Subscription pricing is determined by: Learn more about the cookies we use and how to change your settings. Add to Alert PDF. Requirements for screw-threaded weight-bearing connectors are specified in ISO 2.

Top Gage Crib Worldwide, Inc. Requirements for the application of cones and sockets are not included, but are or will be given in the relevant International Standards for specific medical devices and accessories.

  ANEMIA NORMOCITICA HIPOCROMICA PDF

Click to learn more. It does not specify the medical devices and accessories on which these cones and sockets are to be provided. Annex A includes a figure and a table detailing plug and ring test gauges that are used to check conical connectors made of materials other than metal. Requirements for the application of conical connectors are not included in this part of ISObut are or will be given in the relevant International Standards for specific medical devices and accessories.

Test methods, Conical shape, Plug gauges, Pipe fittings, Hose connectors, Locking and locating devices, Tubing medicalMedical breathing apparatus, Size, Ring gauges, Anaesthetic equipment, Medical equipment, Pipe connections, Anaesthesiology, Dimensions.

Accept and continue Learn more about the cookies we use and how to change your settings.

IS/ISO 5356-1: Anaesthetic and Respiratory Equipment – Conical Connectors, Part 1 Cones and Sockets

We have no amendments or corrections for this standard. You may delete a document from your Alert Profile at any time. You may find similar items within these categories by selecting from the choices below:. This part of ISO does not specify the medical devices and accessories on which these connections are to be provided.

Standards Subsctiption may be the perfect solution.

Find Similar Items This product falls into the following categories. Search all products by. Take the smart route to manage medical device compliance.

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. This part of ISO gives requirements for the following conical connectors: Error corrections in, or comments about, the above data can be sent to: The cones and sockets are therefore not regarded as devices in their own right.

BS EN ISO 5356-1:2015

Figure 1, detailing the dimensions and tolerances of metal conical connectors, has been prepared in accordance with ISO Your Alert Profile lists the documents that will be monitored. You can download and open this file to your own computer but DRM prevents opening this isk on another computer, including a networked server. Cones and sockets Status: This standard is not included in any packages. You may experience issues viewing this site in Internet Explorer 9, 10 or This standard is also available to be included in Standards Subscriptions.

  4066BC DATASHEET PDF

Proceed to Checkout Continue Shopping.

ISO Anesthetic and Respiratory Conical Connector Gages

Items of medical equipment, such as a humidifier or a spirometer, are often incorporated into the breathing system which may also be connected to an anaesthetic-gas scavenging system.

An important consideration is that conical connections need to be secure but nevertheless disconnectable by the operator.

Please first log in with a verified email before subscribing to alerts. Worldwide Standards We can source any standard from anywhere in the world. The use of connectors meeting the requirements of this part of ISO will not necessarily prevent them being disconnected accidentally. Your basket is empty. Annexes B, C and D provide test methods for latching connectors, Annex E includes a figure and table detailing plug and ring test gauges that may be used to check metal conical connectors, and Annex F contains recommendations for testing security of latching connectors.

Connections for these purposes are usually cone and socket joints, and a lack of standardization of these connections has given rise to problems of interchangeability when connecting equipment made by different manufacturers. ISO Scope This part of ISO specifies dimensional and gauging requirements for cones and sockets intended for connecting anaesthetic and respiratory equipment, e.