ASTM D2061 PDF

This standard is issued under the fixed designation D ; the 1 These test methods are under the jurisdiction of ASTM Committee D13 on. Buy ASTM D Standard Test Methods for Strength Tests for Zippers from SAI Global. ASTM D Standard Test Methods for Strength Tests for Zippers.

Author: Faerisar Goltikinos
Country: Jamaica
Language: English (Spanish)
Genre: Photos
Published (Last): 19 November 2010
Pages: 262
PDF File Size: 4.42 Mb
ePub File Size: 14.66 Mb
ISBN: 231-8-97343-121-8
Downloads: 83631
Price: Free* [*Free Regsitration Required]
Uploader: Fauramar

Apply an initial load of 4. Record the nature of the failure and the breaking load to the nearest 2.

ASTM D – 07() Standard Test Methods for Strength Tests for Zippers

The precision and bias of Test Methods D for testing zipper operability are as speci? Set the number of test cycle. Describe the material or product sampled and the method of sampling used.

In case of controversy, the CRE method shall prevail. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every?

Products – Testing Textiles

Read and record the measurement of the de? Not exactly what you want?

You can choose the one which is most convenient or cost effective for you. Have a question about conducting the test for this standard? The components of variance expressed as coefficients of variation, percent relative, were calculated to be: In cases were the puller cannot be inserted due to its thickness, such as a rubber puller, eliminate the rubber for easy gripping.

  DESCARGAR NTC 3588 PDF

A superscript epsilon e indicates an editorial change since the last revision or reapproval. Test modular design, open d22061 management, can realize load, deformation, displacement, variable speed control.

The maximum rotation in Last previous edition approved in as D — Since the tests are inter-related more than one may be needed for a complete evaluation. The ability of the pull and slider to resist the speci? Historical Version s – view previous versions of standard.

We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications. Summary of Test Methods If preferred, the use of a CRT tensile testing machine is permitted. The load shall be measurable in increments of 44 N 10 lbf.

ASTM D2061 resistance strength apparatus puller attachment testing machine equipment

X-ray Fluorescence Analyzer The X-ray fluorescence analyzer is mainly used for screening the content of chemical elements in the semi-finished products, finished zippers and certain raw materials, including lead, cadmium, chromium, mercury, arsenic, barium, antimony and selenium as well as analyzing the unknown components in the samples.

Record any reading above zero as the amount of permanent set. What are your Delivery terms? The enumerated test methods do not provide for the evaluation of all zipper properties. Give our test engineers a call today for help configuring the best test machine and accessories according to your standard.

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

  COMUNICACIONES DIGITALES SKLAR PDF

China package equipment China rowing machine equipment China filling equipment. Examine each specimen to determine whether or not there remains the usual ease of manual movement of the pull.

Recent Posts How many documents do you need to compliance your factory in Bangladesh. In addition the amount of permanent twist imparted to the slider pull or other permanent damage or deformation may be noted.

Secure the stringer in the lower clamp of the testing machine in vertical alignment, positioning the clamps approximately 76 mm 3 in. Two specimens are required. No one test determines the suitability of a zipper for a specific end use.

The specimen is laid on the pad and a load applied. Position the stop along the axis of the clamps and midway between them as shown in Fig.

Reciprocating Test for All Zippers: BS 3084, DIN 3419, ASTM D 2061, JIS S 3015

Record the nature of the failure and the load at failure to the nearest 0. All methods are not suitable for use with all kinds of zipper.

Apply an increasing load until the stop pulls off, until the tape breaks, or until failure of some other kind occurs.

Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.